SCANMASKIN 32 WORLD SERIES
E21
Over temperature
E25
Short circuit in motor
E37
Safe Stop
E038
Overload during low speed
E41
Communication Error
E81
Speed reference error
We strongly recommend that you first find the cause of the fault before clearing it.
Table 53 Error codes
www.scanmaskin.com
The internal temperature in the inverter
is above 120°C (248°F). This could be
caused by faulty ventilation in the electri-
cal cabinet.
The cable to the motor has been dam-
aged
The motor has been damaged
Emergency is active
Communication fails between motor
drive and PLC (DSP machines)
The potentiometer on the control panel
is damaged
Inspect the ventilation fans
Inspect the filters to the fans
Contact Scanmaskin service centre
Inspect the motor cable
Inspect the motor connection
Contact Scanmaskin service centre
Reset the Emergency stop
Increase the speed
Check the RJ45/Ethernet cable
Inspect the potentiometer
Replace if necessary
ENGLISH
101