1.5 Cooling liquid

1.5.1 Personal protection

Product harmful if swallowed. Can cause irritation
to eyes, mucous membranes and skin.
Use rubber gloves to prevent contact.
Use safety goggles to prevent accidental splashes.
Wear ordinary work clothes to prevent contact with
the skin.

1.5.2 Disposal

Any leaks or remains of product, after it has been
used, must be treated in a suitable purification plant
or recycled if possible. Do not discharge the used
product into watercourses, ditches or drainage sys-
tems. The diluted fluid should not be discharged into
the sewers unless permitted by the local regulations.

2 INSTALLATION

Installation should be performed only by expert
personnel authorised by the manufacturer.
During installation, ensure that the power source is
disconnected from the mains.
2.1 Lifting, transport and unloading
procedures
- The system is not equipped with specific lifting gear.
Do not underestimate the weight of the equip-
ment: see technical specifications.
Do not move or position the suspended load
above persons or things.
Do not drop or apply undue pressure on the
equipment.
12

2.2 Positioning of the equipment

Keep to the following rules:
- Provide easy access to the equipment controls and connec-
tions.
- Do not position the equipment in very small spaces.
- Do not place the equipment on surfaces with inclination
exceeding 10° from to the horizontal plane.
- Position the equipment in a dry, clean and suitably ventilated
place.
- Protect the equipment against pouring rain and sun.

2.3 Connection

The cooling unit is provided with a connector J1 for connection
to the power source.
Disconnect the power supply before every opera-
tion!
- Connect the male connector J1 of the cooling unit to the
female connector J2 of the power source.
2.4 Installation
- Put the WU on the GT and block it with the 4 screws (1).
- Position the power source above the cooling unit and secure
it by means of the screws (2).

Publicidad