Always disconnect the appliance from the
electricity main before making any adjustments.
All seals must be replaced by the technician at
the end of any adjustments or regulations.
10) TAPS
"Reduced rate" adjustment -Switch on the
burner and turn the relative knob to the
"Reduced rate" position (small flame fig. 1).
- Remove knob "M" (fig. 14 and 14/A) of the tap,
which is simply pressed on to its rod. The by-pass
for minimal rate regulation can be: beside the tap
(fig. 14) or inside the shaft. In any case, to access
to regulation, it can be done trought the insertion
of a small screwdriver ''D'' beside the tap (fig. 14)
or in the hole ''C'' inside the shaft of the tap
(fig 14/A). Turn the throttle screw to the right or left
until the burner flame has been adequately
regulated to the "Reduced rate" position.
The flame should not be too low: the lowest small
flame should be continuous and steady. Re-
assemble the several components.
It is understood that only burners operating
with G20 gas should be subjected to the above
mentioned adjustments. The screw must be
fully locked when the burners operate with G30
or G31.
ADJUSTMENTS
FIG. 14
30
FIG. 14/A