Installation
Figure 5
5A. Power Supply: This pump requires a 115 V.,
60 Hz., 15 amp individual branch circuit. The
circuit must be grounded and should be
dedicated to the sump pump.
5B. The pump is supplied with a 3-wire cord set with
grounding-type plug. Plug the switch directly into
the outlet and plug the pump into the opposite
end of the switch's plug.
Electrical shock hazard. Always
ground the pump to a suitable electrical ground,
such as a grounded water pipe, a properly grounded
metallic raceway, or a ground wire system. Do not
cut off the round ground pin.
For parts or assistance, call Master Plumber Customer Service at 1-800-628-9439
Figure 6
6A. After you have installed the piping, check valve,
and float switch, the pump is ready for operation.
6B. Check the pump by filling the sump with water
and observing the pump's operation through one
complete cycle. For switch settings see the
Electrical and Switch Specifications chart on
Page 5.
Risk of flooding. Failure to make this
operational check may lead to improper operation,
premature failure, and flooding.
4