Second step is to verify the PLUMP (Vertical) laser beam calibration
An 8 ft clear floor space is required for this procedure.
A door jamb is ideal for this leg of the procedures. It eliminates the requirement of
accessing the ceiling for calibration verification, and the use of a ladder. However, if a
ladder is to be used, please refer to the ladder manufacturer's instructions for its use,
safety and precautions. When using door jamb for this leg of the operation, identify a plump
spot on the floor and mark it with a painter's tape for future reference.
1.
Place the Laser Level on the floor and push the Power Buttom
LOCKED position for now). Make sure to see a solid laser line on the floor. If the floor
surface is reflective, laser beam may not easily be seen. In this case, adhere a
6 ft long painter's blue tape on the floor, in front of the beam.
2.
Slide the Pendulum Switch
stabilize. Use a marker and draw a 1 in long line in the center of the beam in front of the tool.
3.
Walk to the other side and draw a 1 in long line at the center of the laser beam at
the other end of the tape.
4.
Cut a 2 in long strip of painter's blue tape. Draw a solid 1 in long line at the center of
the tape strip. Place this tape strip over the laser beam on top of the door jamb or the
ceiling. The drawn line should coincide with the center of the laser beam.
5.
Slide the Pendulum Switch
6.
Relocate the tool to the opposite side and place it at the adge of the painter's blue
tape. Slide the Pendulum Switch
the beam to stabilize.
7.
Align the beam with the two pre-scribed lines on the tapes. Inspect the beam position
and the scribed line on the overhead tape. Measure the distance between the
scribed line and current beam (center of the beam) and if the deviation is withing
the tolerances, the Plumb (vertical) laser is also within the calibration limits.
8.
The tool is ready for use.
9.
For slope alignment, the pendulum should be in the LOCKED position. Press the
ON/OFF switch to activate the laser beam. You can safely tilt the tool.
PLEASE NOTE: In the LOCKED position, the laser beam will flash once every 5 sec.
10. With the Pendulum in the OFF position, you can press the ON/OFF button
turn on the laser beam in either one of the three positions: Cross, Level or Plumb.
When the laser beam is switched ON, it will always default to the previous setting mode.