ADJUSTING PRO LINK BASIC
Pro Link Basic allows the settings to be changed on the receiver. The settings and how to adjust them will be explained in the following section.
Setting the receiver
Pro Link Basic has two set points:
•
Set point 1: Relay 1 is drawn.
•
Set point 2: The receiver can be set so that relay 1 remains drawn at the same time as relay 2 is drawn or so that only relay 2 will be used.
The polarity is set on dip switch 1.
NOTE: The output of the valve motor will always open at set point 2 regardless of the setting on the dip switch.
ON
1 2 3 4
Relay 1 and relay 2 will remain drawn on set point 2.
The polarity of the connection to the PCB can be reversed if a connection error occurs when the valve motor is connected to the PCB. The polarity
is reversed on dip switch 2:
ON
1 2 3 4
Standard polarity for valve motor connection
OBS: Sætpunkt 2 kan kun ændres på de emhætter, der har WF/BT
DIP
DIP
ON
1 2 3 4
Relay 2 will draw on set point 2.
ON
1 2 3 4
Reversed polarity for valve motor connection