M 536991501901122020
MOUNTING OF VALVE MOTOR
The valve motor must be mounted on the valve prior to installing the vent. This is performed in the following steps:
1
x1
Make a measurement for mounting the valve
motor bracket onto the flange of the vent.
NOTE: Take special care to ensure that the
bracket is centred.
MOUNTING THE VALVE ON THE PIPING SYSTEM OF THE VENTILATION SYSTEM
For best results, the valve can be mounted on the piping system of the ventilation system so that the air drawn through the valve is mixed with
the heated supply air from the ventilation system. This reduces the downdraft and draft from the air vents for unbalanced operation.
2
x1
Mount the bracket of the valve motor onto the
flange of the valve using the self-tapping screw.
THERMEX PRO LINK III
3
Install the valve motor by mounting it on the
valve shaft, and follow this by attaching the
motor to the bracket.
67