OBJ_DOKU-36146-003.fm Page 25 Friday, February 19, 2016 9:59 AM
Continuous Laser Beam
Do not point the laser beam at persons or animals and
do not look into the laser beam yourself, not even from
a large distance.
In this setting, the laser beam also remains switched on be-
tween measurements; for measuring, it is only required to
press the measuring button 2 once.
Measuring Functions
Simple Length Measurement
For length measurements, press button 12 until the "length
measurement" indication appears on the display.
To switch the laser on and for measuring,
briefly press the measuring button 2 once
each time.
The measured value is displayed in the re-
sult line c.
For several subsequent length measure-
ments, the last measured results are displayed in the mea-
sured-value lines a.
Area Measurement
For area/surface measurements, press button 12 until the in-
dicator for area measurement
Afterwards, measure the length and the width, one after an-
other, in the same manner as a length measurement. The laser
beam remains switched on between both measurements.
Upon completion of the second measure-
ment, the surface is automatically calcu-
lated and displayed in the result line c.
The individual measured values are dis-
played in the measured-value lines a.
Volume Measurement
For volume measurements, press button 12 until the indica-
tor for volume measurement
Afterwards, measure the length, width and the height, one af-
ter another, in the same manner as for a length measurement.
The laser beam remains switched on between all three mea-
surements.
Upon completion of the third measure-
ment, the volume is automatically calcu-
lated and displayed in the result line c.
The individual measured values are dis-
played in the measured-value lines a.
Values above 1000000 m
dicated; "ERROR" appears on the dis-
play. Divide the volume to be measured into individual mea-
surements; their values can then be calculated separately and
then summarized.
Continuous Measurement (Tracking) / Minimum/Maxi-
mum Measurement (see figure B)
For continuous measurements, the measuring tool can be
moved relative to the target, whereby the measuring value is
updated approx. every 0.5 seconds. In this manner, as an ex-
Bosch Power Tools
ample, you can move a certain distance away from a wall,
while the actual distance can always be read.
For continuous measurements, press function mode button 8
until the indicator for continuous measurement appears on
the display. To start the continuous measurement, press the
measuring button 2.
The minimum measurement is used to determine the shortest
distance from a fixed reference point. It is used, as an exam-
ple, for determining plumb lines or horizontal partitions.
The maximum measurement is used to determine the greatest
distance from a fixed reference point. It is used, as an exam-
ple, for determining diagonals.
The previous minimum and maximum values are deleted by
pressing the button for clearing the internal memory 4.
Pressing the measuring button 2 ends the continuous mea-
appears on the display.
surement. The last measured value is displayed in the result
line c. Pressing the measuring button 2 again restarts a con-
tinuous measuring run.
Continuous measurement automatically switches off after
5 min. The last measured value remains indicated in the result
line c.
Indirect Distance Measurement
Note: Indirect distance measurement is always less accurate
than direct distance measurement. Depending on applica-
tion, greater measuring errors are possible than with direct
distance measurement. To improve the measuring accuracy,
we recommend using a tripod (accessory).
appears on the display.
The indirect distance measurement is used to measure dis-
tances that cannot be measured directly because an obstacle
would obstruct the laser beam or no target surface is available
as a reflector. This measuring procedure can only be used in
vertical direction. Any deviation in horizontal direction leads
to measuring errors.
The laser beam remains switched on between the individual
measurements.
For indirect length measurements, three measuring modes
are available. Each measuring mode can be used for deter-
mining different distances.
3
cannot be in-
a) Indirect height measurement (see figure C)
Press the function-mode button 8 until the indication for indi-
rect height measurement
Pay attention that the measuring tool is positioned at the
same height as the bottom measuring point. Now, tilt the
measuring tool around the reference plane and measure dis-
tance "1" as for a length measurement.
English | 25
The current measuring value is displayed
in the result line c. The maximum ("max")
and the minimum ("min") measuring val-
ue are displayed in the measured-value
lines a. It is always overwritten when the
current length measurement value is less
than the present minimum or larger than
the present maximum value.
appears on the display.
1
1 609 92A 25T | (19.2.16)