1 • INSTALLATION
• Dimensions and cut-out; panel mounting
63
48
48
99
10
108
96
48
44,5
105
10
Panel mounting:
Fix the device with the bracket provided before making any electrical connections.
To mount two or more devices side by side, use the cut-out dimensions shown above.
CE MARKING: EMC (electromagnetic compatibility) conformity to EEC Directive
89/336/EEC with reference to the generic Standard EN50082-2 (immunity in industrial
environments) and EN50081-1 (emission in residential environments). BT (low voltage)
conformity to Directive 73/23/EEC as modified by Directive 93/68.
MAINTENANCE: Repairs must be done out only by trained and specialized personnel.
Cut power to the device before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene, etc.).
Use of these solvents can reduce the mechanical reliability of the device. Use a cloth
dampened in ethyl alcohol or water to clean the external plastic case.
SERVICE: GEFRAN has a service department. The warranty excludes defects caused
by any use not conforming to these instructions.
40T 48 / 40T 96
UNIVERSAL TEMPERATURE and PRESSURE INDICATOR - ALARM UNIT
70
70
45
45
115
70
92
!
For correct and safe
installation, follow the
instructions and
observe the warnings
contained in this
manual.
USER'S MANUAL
SOFTWARE VERSION 1.0x / 2.0x
code 81641 / edition 0.5 - 07/01
25050 Provaglio d'Iseo (BS) ITALIA
ISO 9001

TECHNICAL SPECIFICATIONS

2 •
Display
Keys
Accuracy
Resolution
(function of settable sample time)
Main input
Thermocouples
Cold junction error
RTD type (scale configurable within indi-
cated range, with or without decimal point)
Max. RTD line resistance
PTC type / NTC type
Max. non-linearity error
°C / °F selection
Linear scale ranges
Logic input
Function of logic input
Alarms (Trip points)
Alarm masking
Relay contact
Logic output
Triac output (only for 96 format)
Fault settings
Transmitter / Sensor Power Supply
(option)
Analog retransmission (option)
Power supply (switching)
Fuse (inside device, not
operator serviceable)
Faceplate protection
Working / Storage temperatures
Relative humidity
Installation
Weight
EMC conformity has been tested with the following connections
FUNCTION
TC input probe
"PT100" input probe
Power supply cable
Relay output cables
10
GEFRAN spa via Sebina, 74
Tel. 0309888.1 - Fax 0309839063
Internet: http://www.gefran.com
3, 4 digit red LED's
mod. 48 digit height 10mm (4 digits)
mod. 96 digit height 20mm (3 digits),
digit height 14mm (4 digits)
3 mechanical keys (Raise, Lower, F)
0.2% f.s. at 25°C ambient temperature, ts=120msec
120msec, >13bit - 8000 points
60msec, >13bit - 8000 points (only for linear inputs)
30msec, >12bit - 4000 points (only for linear inputs)
15msec, >11bit - 2000 points (only for linear inputs)
TC, RTD, PTC, NTC
60mV, 1V, 5V, 10V, Ri ≥ 500KΩ
20mA, Ri = 50Ω; adjustable digital filter
J, K, R, S, T, B, E, N
(IEC 584-1, CEI EN 60584-1, 60584-2)
L GOST, U, G, D, C
Custom linearization available on request
0,1° / °C
DIN 43760 (PT100), JPT100
20Ω
990Ω, 25°C / 1KΩ, 25°C
See t.P parameter at page 4
Faceplate configurable
-1999 to 9999 (with 4 digit display)
-999 to 999 (with 3 digit display - only for model 96)
Configurable decimal point position, possible 32
segment linearization
Ri = 5,6KΩ (24V, 4mA), isolated to 1500V
configurable to reset memory latch, hold,
flash, zero, select max./ min. peak, peak-peak value
Maximum of three configurable alarms:
absolute, deviation, symmetrical deviation.
Adjustable hysteresis
- exclude on power-up
- latch reset from key and/or external contact
- insert delay filter (DON, DBI, DOF, DPO)
- set minimum intervention time
NO (NC) 5A, 250V
11Vdc, Rout = 220Ω (6V/20mA)
20...240VAC ±10%, 3A max
Snubberless, inductive and resistive load I
Alarm states can be configured in probe fault
condition
24V ±10%, 50mA
15V for transmitter, max. 50mA
1.2V for potentiometer > 100 Ω
4 to 20mA, max. 150 Ω load
(standard) 100...240VAC/DC ±10%, 50/60Hz, 7.5VA
(optional) 11...27VAC/DC ±10%, 50/60Hz, 7.5VA
100 to 240VAC/DC - type T - 500 mA - 250V
11 to 27VAC/DC - type T - 1,25 A - 250V
IP65
0 to 50°C / -20 to 70°C
20 to 85%, non-condensing
Panel mounting, extractable from front
160g (mod. 48); 320g (mod. 96) for the complete version
CABLE
0.8 mm
compensated 5 m
2
1 mm
2
1 mm
2
1 mm
2
2
2
t = 128A
S
LENGTH USED
3 m
1 m
3.5 m