Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
EN
MAX 100 cm
(14)
(16)
MIN 35 cm
Fig. 6&7
Schémas 7 et 8
HOW TO INSTALL THE WINDOW SEAL KIT
The window seal kit is included in the reference AU5610F0/AU5620F0. It can be bought as a Rowenta
accessory with reference XD6620F0 (#16). Before installation, check that the adhesive gripping tape
do not damage your window.
1. Open the window and clean the surfaces to remove dust and grease on the
window frame and casement.
Stick the strip to the frame. Do not stick it to the contact surface of the window
seal (you must be able to close the window).
2. Stick the strip to the outside or inside of the window casement ( handle side).
Ensure that the window can be closed.
Before sticking together, make sure the sticky surface does not damage the
window frame.
3. Leave the window open. First stick the wide side of the window form (zip
closed) from the center to the right and left hand sides or to the top and bottom
to the window frame.
4. Close the window and make sure that it does not clamp the window form.
Stick the narrow side of the window form (zip closed) from the center to the
right and left hand sides or to the top and bottom to the casement.
5. Open the window slightly to have the exhaust hose into the window form by
using the zipper.
(16)
(16)
(16)
18

CONTROL PANEL

(B)
(A)
(C)
(D)
Power Control (A)
The power control turns the unit on and off. After switching the air conditioner off, you must wait 3
minutes before switching it back on again.
Warning Light "FULL " (B)
Condensed water may accumulate in the unit.
If the internal tank becomes full, the warning light will come on and the unit will stop operating
until the unit has been drained (evacuation #9). To drain the unit, refer to PRECAUTIONS OF USE
(storage) page 14.
Eco mode (C)
Operation only in the 2 modes below by pressing the ECO button.
• Cooling mode
: in this mode, the target temperature is automatically set to -3°C from the room
temperature to save energy. The speed is set automatically. After 3 seconds, the display will return
to the room temperature.
When the target temperature is reached, the compressor stops but the ventilation continues at
speed 1 in order to circulate the air in the room
• Fan mode
: the fan speed is automatically adjusted according to the temperature.
Speed 3 if the room temperature is above 28°C.
Speed 2 if the room temperature is between 25°C and 28°C.
Speed 1 if the room temperature is below 25°C.
Mode Control (D)
The mode control has three settings. A light indicates which mode is currently being used.
• Cooling mode
: During the cooling mode the air is cooled and hot air is expelled through the
heat exhaust hose (#11). Adjust fan speed and air temperature to suit your desired comfort level.
Use the buttons (-) and (+) to set the desired temperature between 16 and 32°C. After 10 seconds
the display will revert to room temperature. Note: the air exchange hose must vent outside the
room when using cooling mode.
• Dehumidify mode
: Air is dehumidified as it passes through the unit, without being in full
cooling mode. In this mode, If temperature is higher than 25°C, fan speed can be adjusted;
otherwise, fan speed is fixed to "low" . In this mode, do not connect the exhaust hose and let the
warm air return to the room. You will need to drain the unit to evacuate the water : refer to PRE-
CAUTIONS OF USE (storage) page 14.
• Fan mode
: air is circulated throughout the room with no cooling. The air exchange hose does
not need to be installed in this mode Adjust fan speed to suit your desired comfort level.
(E)
(F)
(G)
19
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido