8. Approvals
The standard version of DWK pumps has been
tested by TÜV, in relation to EC Council Directive 98/
37/EC Machinery, registration no. AM 5014341 3
0001 and report no. 13009106 001.
9. Type key
The pump can be identified by the type designation
stated on the pump nameplate. See section
7.
Nameplate.
Code Example
DWK Dewatering pump
O
Semi-open impeller
E
Enclosed impeller
Strainer hole size:
6
Maximum solids size [mm]
Pump outlet:
50
Nominal diameter of pump outlet port [mm]
Code for output power, P2:
075
P2*: Code number from type designation / 10 [kW]
Equipment:
-
Standard
S
Sensor
Frequency:
5
50 Hz
6
60 Hz
Voltage and starting method:
0D
380-415 V, DOL
1D
380-415 V, Y/D
0E
220-240 V, DOL
1E
220-240 V, Y/D
Material in pump
[ ]
Standard
R
Cast iron pump with high-chrome stainless steel impeller and stainless steel inlet strainer
*
Exception: Code 075 = 0.75 kW
DWK
.O
.6
.50 .075 .S .5 .0D
.R
9