Wall bracket
Figure 9
(1) Display position
(2) Wall bracket
(3) Ventilation openings
(4) Slotted link for suspension bolts
(5) Suspension bolts
(6) Locking screw
(7) Recess handle
(8) Second inverter
Mount the wall bracket as follows:
•
Unscrew the wall bracket (2) from the rear of the inverter.
•
Two locking screws hold the inverter in the wall bracket.
•
A paper strip with printed lock marks the locking screw (6). Do not remove the pa-
per strip!
•
Use the wall bracket to mark out the mounting holes.
•
Keep dimensions and distances.
•
Keep a minimum distance of 50 cm from the floor.
•
The contour of the display position (1) is punched into the wall bracket.
•
The display position (1) of the REFUSOL
•
Drill the mounting holes and apply dowels.
•
Screw the wall bracket (2) to the wall.
24
8
Distances for positioning the wall bracket
®
series is identified with TL.