Page 6
ENGLISH
Pump
Figure 1.
Basic Plumbing Diagram for Laminar Jet with Deck Canister
"B" - Plumbing
Loop
Check Valve
"D" - Bypass/Bleed Off Line
Figure 2.
Plan View of Plumbing Loop for Multiple Laminar Jets
Jandy
Laminar Jet | Installation and Operation Manual
®
Filter
Check Valve
"A" - Main Feed Line
Jandy 3-Port Valve
P/N 4715 if " A " is 1½ " (38 mm) or
P/N 4717 if " A " is 2 " (50.8 mm )
Note: If using a high head pump,
plumb a cartridge filter inline.
Water Height
7' (2.1 m) Maximum
Low Voltage
Transformer
(1.8 m)
Deck Canister
"C" - Inlet Lines to
Laminar Jet Deck Canister
(Maximum 6 Lines per
Plumbing Loop)
Table 1.
Multiple Jet Setup
Number of
Recommended Pipe Size within
Laminar Jets
25' (7.6 m) of equipment (in/mm)
at rate of
10 gallons per
A
min (38 lpm)
2
1½ / 38
3
1½ / 38
4
2 / 50.8
5
2 / 50.8
6
2 / 50.8
Water Throw
8' (2.4 m) Maximum
Jandy Laminar
Nozzle
6'
max
B
C
1 / 25.4
1 / 25.4
1½ / 38
1 / 25.4
1½ / 38
1 / 25.4
1½ / 38
1 / 25.4
1½ / 38
1 / 25.4
D
1½ / 38
1½ / 38
2 / 50.8
2 / 50.8
2 / 50.8