1.0 Relationship to the
authorities
Soap stone surround for Jøtul I 150 FL
The insert is intalled in accordance with the installation and user
instructions for Jøtul I 150 FL (cat. no. 220294).
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including those that refer to national and
European standards, shall be complied with when installing
the product.
Instructions for mounting, installation and use are enclosed with
the product. Prior to using the product the installation must be
inspected by a qualified person.
A product data label in heat resistant material can be found
on the heat shield at the back of the product. This contains
information about identification and documentation for the
product.
2.0 Technical information
(fig. 1)
Height:
1,315 mm
Width:
610 mm
Depth:
406,5 mm
Weight of surround:
50 kg
Weight including insert:
349 kg
Optional equipment:
Front elements in rough structure
Stone for side flue
Floor plate
All manuals and user guides at all-guides.com
3.0 Installation requirements
3.1 Distance from product to flammable
material:
See fig. 1
3.2 Foundations
Ensure that the floor is strong enough for the fireplace. See "2.0
Technical data" for weights.
3.3 Floor coverage requirments
The entire floor within the surround must be covered by a steel
plate (minimum thickness 0.9 mm) if the fireplace is to stand
on a floor of combustible material.
Any flammable flooring material must be removed from the
area under the fireplace and floor plate.
3.4 Standard front plate requirements
In front of the fireplace a plate made of steel or other non-
flammable material should be used.
Contact your local building authority regarding restrictions and
installation requirements.
3.5 Air circulation requirements
Air shall be allowed to circulate between the insert and the
surround. This is to ensure that heat build-up in the surround
is acceptable and so that there is sufficient heat transmitted
into the room.
N.B: The knock out part at the bottom of the heat shield must be
removed. See fig. 1 for distances.