All manuals and user guides at all-guides.com
Replacing the cable
The cable is replaced as follows:
- Disconnect the power supply.
- Open the terminal block cover (fig. A).
A
- Connect the power supply cable as shown in
the figure, remembering that the yellow-green
lead is the earth.
- The cable must always be secured by the
cable grip (fig. B) on the terminal block, so
that it cannot rotate or become detached; it
must not come into contact with temperatures
above 75°C at any point.
- The connection plug must comply with
regulations and be sized for the load of the
appliance.
CAUTION: The power supply cable must
B
comply with current regulations and have the
following characteristics: three-wire cable
with minimum section of 1.5 mm².
THE MANUFACTURER ACCEPTS NO
CIVIL OR CRIMINAL LIABILITY IF
THE CONNECTION IS NOT MADE IN
COMPLIANCE WITH CURRENT
REGULATIONS.
This appliance complies with the current EC
regulations 87/308; 73/23; 93/68 and 89/336.
38