Technical Data; Overall Dimensions; Working Field - Riello Burners 40 FSP10 Instrucciones De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.

TECHNICAL DATA

2.1 TECHNICAL DATA
Thermal power
LPG
(Family 3)
Electrical supply
Motor
Capacitor
Ignition transformer
Absorbed electrical power
(1) Reference conditions:
COUNTRY
GAS CATEGORY

2.2 OVERALL DIMENSIONS

305
D4251

2.3 WORKING FIELD

1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
40
D5256
40,000
3290
(1)
42 – 116 kW
Net heat value: 24.44 kWh/Sm
Pressure: 12 - 100 mbar
Single phase, 230 V
230V / 0.7 A
4 µF
Primary
230V / 1.8 A
0.13 kW
Temp. 15°C - Barometric pressure 1013 mbar – Altitude 0 m above sea level.
DE
AT
II 2ELL3B/P
II 2H3B/P
Burner
33
Combustion head extension, supplied separately.
(as EN 676)
50
60
70
50,000
60,000
-
36,000 – 100,000 kcal/h
3
=
21,000 kcal/Sm
~
±
10%
50Hz
-
Secondary 8 kV / 30 mA
FR
ES - GB - IE
II 2Er3P
II 2H3P
110
346
170
61
80
90
70,000
80,000
2
GB
3
LU
II 2E3B/P
Flange
185
130
100
110
120
90,000
100,000
Thermal power
NL
II 2L3B/P
kW
kcal/h

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

564 t303756439

Tabla de contenido