Assembly
Important! The fitting must be installed, flushed and
tested after the valid norms.
Technical Data
This mixer series-produced with water-dimmer
(flow limiter)
16510XXX:
Rate of flow with EcoSmart:
Rate of flow without EcoSmart:
16803XXX:
Rate of flow with EcoSmart:
Rate of flow without EcoSmart:
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temperature:
The hot and cold supplies must be of equal pressures.
Hansgrohe mixers can be used together with hydraulically
and thermically controlled continuous flow heaters if the
flow pressure is at least 0.15 MPa.
If the continuous flow heater makes any problems or there
comes not enough water, the EcoSmart (4a) located behind
the mousseur must be removed.
8
English
Spare parts (see page 3)
1
2
3
4
5
®
6
7
8
5 l/min 0.3 MPa
13 l/min 0.3 MPa
9
10 diverter knob
11 l/min 0.3 MPa
11 flange
12 l/min 0.3 MPa
12 spout large model 16803XXX
max. 1 MPa
13 aerator cpl. 16803XXX
0,1 - 0,5 MPa
1,6 MPa
Special accessories
max. 80° C
X
65° C
XXX = Colors
000 chrome plated
820 brushed nickel
830 polish nickel
handle
screw cover
sleeve
aerator cpl. 16510XXX
spout 16510XXX
shut off unit
fixation set
connection hose 450 mm
connection hose 900 mm
pull rod
special tool set
(order as an extra)
16597XXX
97987000
97993XXX
95387XXX
97990XXX
94009000
96078000
94071000
97202000
94067000
98619XXX
98620XXX
98616XXX
98617XXX
58085000