8. PRODUCT DISPOSAL

When it is time to dispose of the pump, it does not contain
any toxic or polluting material. The main components are
properly identified for selective disposal.
Disposal of this product or parts of it must be carried out
in an environmentally friendly manner. Use your local
waste collection service. If this is not possible, please
contact your nearest ESPA service.
LINE RUN FAULT Equipment Status
1
1
0
Normal operation. Pump is running.
1
3
0
Flow rate too low. If it remains in this state for more than 10 sec. the pump will stop.
LINE RUN FAULT Equipment status
1
0
0
Normal operation. The pump is waiting for a flow request.
Lack of tank level. When the water level recovers, the pump starts automatically.
1
2
0
Dry running error. The pump has stopped due to lack of water and the equipment is
1
0
3
cycling through the automatic restart attempts. .
Dry running alarm. The equipment is stopped due to lack of water until the manual
1
0
1
reset is carried out.
Lack of pressure alarm. If the unit detects water circulation and the pressure is
below 0.3 bar. The pump stops. It must be reset manually.
1
3
3
1 0 4 Pressure transducer alarm. If communication is restored, the unit starts up
automatically.
Pressure transducer alarm. If communication is restored, the unit starts up
1
0
4
automatically.
Current error. The pump has stopped due to an overcurrent and the equipment is
1
2
2
cycling through the automatic reset attempts (4).
Current alarm. The equipment is stopped due to overcurrent until the manual reset is
1
2
1
carried out.
Short circuit error. The pump has stopped due to an overload and the unit is making
1
4
4
the cycle of attempts for automatic reset (4).
Short circuit alarm. The equipment is stopped due to overloads until the manual
1
4
1
reset is carried out.
Voltage error. When the power supply voltage recovers within the established
2
0
2
margins, the pump will start up automatically.
Internal alarm. Electronic communication failure. Disconnect the pump from the
power supply and reconnect by pressing (+) and (-) simultaneously. Depending on
1
0
2
the fault, the equipment will restart or remain in fault mode.
Led's position when the pump is running
Led's position when the pump is stopped
15

9. TECHNICAL DATA

Liquid temperature:..................4.ºC - 40ºC
Ambient temperature:............ . 0ºC - 40ºC
Storage temperature:.............-10ºC - 50ºC
10. LED INDICATORS (TECNOPLUS 25 Model)
When the equipment is switched on, a sequence is
initiated:
1.The LEDs light up twice consecutively.
2.The unit starts up.
The possibilities of the LED'S are
0=Led OFF
1=Led ON
2=Slow flashing LED (2s. On/2s. Off)
3=Fast flashing LED (1s. On/1s. Off)
4=Led flashing very fast (0.2s. On/0.2s. Off)