Troubleshooting
ProPass Troubleshooting Guide
If the problem is still occurring after all the checks listed
below have been completed, contact an authorized
TYCROP Distributor for service.
Symptom
Conveyor belt will not turn
Option will not operate
Conveyor belt is jerking
Hydraulics are noisy
Maintenance Instructions
All manuals and user guides at all-guides.com
TYCROP Manufacturing Ltd.
The hydraulic hose lines are not connected to the tow vehicle.
The setting on the conveyor belt's flow control valve is not over #5–6 on SH models.
The conveyor belt switch on the on/off pendant is off for SH models.
The conveyor belt option on the control pendant is off for EH models.
The remote switch is off for the EH models.
There is insufficient hydraulic pressure from the tow vehicle or Hydraulic Power Pack
(as indicated by the pressure gauge on the ProPass). See Specifications.
The vehicle's hydraulic reservoir tank is low on oil.
The four-prong power supply cord from the ProPass is not connected to the tow vehicle
during operation for SH models.
The conveyor belt's solenoid doesn't have 12 V; and check fuses.
The 15 A fuse behind the front hydraulic valve panel is burnt out.
The wiring harness isn't fully connected (if there is no power to the solenoid).
The quick disconnect couplers aren't connected properly and in the right order at the
tow vehicle and at the option.
The quick couplers on the option cable are improperly connected.
The option switch on the on/off pendant is off.
The setting on the option's flow control valve isn't above #5.
The four-prong power cord from the ProPass isn't connected to the tow vehicle during
operation.
There is insufficient hydraulic pressure from the tow vehicle (as indicated by the
pressure gauge on the ProPass). See Specifications.
The vehicle's hydraulic reservoir tank is low on oil.
The option's solenoid doesn't have 12 V; and check fuses.
The wiring harness isn't fully connected (if there is no power to the solenoid).
The tow vehicle has insufficient rpm during operation
The hydraulic pressure is inconsistent (as indicated by the pressure gauge on the
ProPass). See Specifications.
The vehicle's hydraulic reservoir tank is low on oil.
The setting on the conveyor belt's flow control valve isn't over #5–6.
The rear drive roller on the conveyor belt is slipping (adjust tension).
The machine has not reached operating temperature, run for approximately 5 minutes.
ProPass 180 Top Dresser Operator's Manual
Cause
Page 47