Pressure generation and air flow
Operation
Connection
Connect the machine to an electrical outlet with a voltage as per the machine's rating plate specifications.
Filter cleaning
The machine has a filter status indicator that lights up when the filter needs to be cleaned or replaced. The filters must be cleaned
1-2 times a day with continuous use .
1.
Leave the machine switched on and close the damper on the cyclone inlet.
2.
Adjust the filter cleaning button.
3.
Wait for 5-10 pulses.
4.
Open the throttle at the cyclone inlet and reset the filter cleaner button.
5.
Check that the pressure gauge indicates green or that the filter indication lamp is off. If not, repeat the procedure. If the
gauge indicates red or the light is on even after repetition, the fine filter needs to be replaced.
Emptying
L – Longopac
Close the bag using the supplied cable ties when you believe that it has been filled to a suitable level. Another cable tie is used a
little further up. This forms the bottom of the next bag. The filled bag is then cut off, and the machine is ready to be used again.
Changing the bag magazine
1.
Rotate the holder to the position in which it can be pulled down.
2.
Insert a bag magazine into the holder and refit it.
3.
Cut the four tapes that hold the bag magazine together and pull the inner end of the bag upwards over the rubber strip. Then
secure the bag with the strap. Pull the outer end over the holder, and tie a cable tie in place as a bottom closure.
0
50
100
150
200
250
DC Tromb 600, 99063-A
Tromb 600
300
350
400
450
500
m3/h
550
600
17