9. TECHNICAL PARAMETERS
Module
Max. PV Power (Wp)
Max Input Voltage (V)
MPP Voltage Range (V)
Min DC Voltage (V)
Nominal DC-input
Voltage (V)
Max. Input Current (A)
Max. Short DC current (A)
No. Of independent
MPPT inputs
No. Of PV strings
per MPPT
Max inverter backfeed
current to the array (A)
Rated Power (W)
Max. Apparent AC
power (VA)
Rated grid voltage (Vac)
Rated power
frequency (Hz)
Max output current (A)
Max output overcurrent
protection (A)
Inrush current (Peak
and duration)*
Max. output fault current
(Peak and duration)*
Adjustable displacement
power factor
EINSOLAR3V
INPUT/DC
4500
500
50-450
40
360
12.5
15.6
1
1
0
OUTPUT/AC
3000
3300
220/230/240
50/60
13.8
20
15A@
0.13ms
45A
@10ns
0.8ind to
0.8cap
20
THDi at rated power
Note: "*" The inrush current and Max output fault
current are really test values.
Max. Efficiency
Euro Efficiency
MPPT Efficiency
Anti-islanding
protection
Input reverse
polarity protection
Insulation resistor
detection
Residual Current
monitoring unit
Output over
current protection
Output Short
Protection
Output Over
Voltage Protection
V.2
<3%
EFFICIENCY
97.6%
97.0%
99.9%
PROTECTION
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
21
V.2