The power supply socket for the apparatus must be
at least 11.5ft from the pool.
Single-phase motors have thermal protec-
tion.
All of three phase motor pumps do not
incorporate this protection. They must be
connected
to
a
breaker that can be adjusted manually. Set
the circuit breaker according to the current
given in the rating plate plus 10%.
Follow instructions given on fig.1 for correct
electrical connection.
3.5. Pre-start checks
Ensure the voltage and frequency of the
supply corresponds to the values indicated
on the electrical data label.
Ensure that the pump shaft is rotating freely.
Fill the pump body with water through the filter
cover to the bottom level of the suction line.
Check all joints and connections for leaks.
Set the prefilter cover back in place and screw it to
a suitable tightness.
THIS PUMP MUST NEVER BE DRY RUN.
4. STARTING
Ensure all valves in the pipework are open.
Connect power supply. There will be a delay before
water appears at the end of the discharge pipe.
Viewings from the fan ensure that the rotation of the
motor is clockwise. On three phase pumps the
motor may rotate anticlockwise. If this is happening,
the flow will be lower than expected. To rectify this
situation the two supply phases need to be re-
versed.
Ensure that the absorbed current is the same or
lower than the maximum shown on the name plate.
Adjust the thermal relay if is necessary.
If the pump fails to operate refer to the possible
faults, causes and solutions list for assistance.
5. MAINTENANCE
Under normal conditions these pumps require no
special or planned maintenance.
Clean the pump with a damp cloth without using
harsh products.
If the pump is not to be operated for a long
period it is recommended to remove it from
the installation, drain down and store in a dry,
well ventilated place.
ATTENTION: In the event of faults or
damage, both the replacement of the supply
cord and the handling of the pump must only
be carried out by an authorised service
agent.
motor-protective
circuit
6. DISPOSING OF THE PRODUCT
When the pump is eventually disposed of, please
note that it contains no toxic or polluting material.
All main components are material identified to allow
selective disposal.
This product or parts of it must be disposed of in an
environmentally
sound
collection service. If this is not possible, contact the
nearest service workshop.
7.
PLATE SHOWING CHARACTERISTICS
DESCRIPTION
1
Item reference
2
Voltage + frequency + item specifications
3
Flow
4
Pressure
5
Nominal voltage, no. stages, alternate current symbol and frequency
6
Capacitor
7
EC mark
8
Humidity protection level
9
Maximum pressure
10
Year and week of manufacture + Pump serial no.
11
Thermal protection incorporated indicator
12
Max. liquid temperature
13
Motor max. nominal output (P2)
14
Electric pump unit absorbed power(P1)
15
Designated motor insulation
16
Continuous operation symbol
17
Maximum nominal intensity at nominal voltage
18
Name and address of vendor responsible for the product
10
EN
way,
use
the
waste