Viewing of screen
Description
PAGE - TEST
Resistance Start-up / Shut-
Ignition resistance
down
Air Start-up / Shut-down
Activates 24V electrovalve power supply for the compressed air kit
Alarm Start-up / Shut-down
Activates the 230V output
Cochlea Shut-down
Internal cochlea
Tank shut-down
External cochlea
Internal Fan
Burner fan
External Fan
Cochlea fan
NOTA
This checks that the main components of the burner are working correctly
REMOTE CONTROL
Must be activated to connect the GSM module to connector 6 on the
Module
burner
2.7.1
Approved calibration
Viewing of screen
Power 1
Fan
Power 2
Fan
Power 3
Fan
Power 4
Fan
Power 5
Fan
NOTA
2.7.2
Alarm messages
In the event of a fault or malfunction, the following signs appear on the screen:
Description
Failed ignition
Blackout alarm
Faulty water probe alarm
TS overheating
2.7.3
Problems - Possible causes -
In the table below are reported the most common problems with their possible solutions.
Problem
Failed ignition
Power supply absent
Water probe
Description
Filling Time from external cochlea to Power 1.
Fan speed at Power 1.
Filling Time from external cochlea to Power 2.
Fan speed at Power 2.
Filling Time from external cochlea to Power 3.
Fan speed at Power 3.
Filling Time from external cochlea to Power 4.
Fan speed at Power 4.
Filling Time from external cochlea to Power 5.
Fan speed at Power 5.
Solutions
Possible cause
Empty pellet container
Disconnected or broken external cochlea cable
Ignition resistance broken
Combuston grill is blocked
Internal cochlea blocked
Electrical supply to burner not present
The probe is incorrectly positioned or connected
Probe faulty
Pellet container empty
Disconnected or broken cochlea cable
Cochlea motor not working
U/M
Field
Factory default setting
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
rpm
0 ÷ 300
rpm
0 ÷ 300
YES / NO
Approved
calibration
U/M
Field
Round 25
Sec
0,0 ÷ 60,0
2,0
rpm
0 ÷ 300
110
Sec
0,0 ÷ 60,0
2,8
rpm
0 ÷ 300
120
Sec
0,0 ÷ 60,0
3,7
rpm
0 ÷ 300
130
Sec
0,0 ÷ 60,0
4,6
rpm
0 ÷ 300
140
Sec
0,0 ÷ 60,0
5,5
rpm
0 ÷ 300
150
Solution
Fill the container
Check the resistance and/or substitute it
Pull out the grill and clean it
Check the internal cochlea and remove any
blockages
Check the mains supply
Check that the electrical cables are connected
correctly
Check that the general switches and the switches
on the burner are in the correct position
Check its position and connections
Replace the probe
Fill the container
Re-establish the connection
Check the motor
IT
OFF
ES
OFF
OFF
OFF
ENG
OFF
RUS
NO
SL
Round 50
2,5
160
4,3
185
6,2
210
7,3
225
8,5
240
37