Ankara 4P - Arka 4P
English
The engine is
• screws and bolts are not tight-
noisy
ened
• the cabinet is not levelled
Condensate
• poor room conditions
• poor air ventilation
• If present, the heating elements
of the glass panels do not work
• the windows are not closed
properly
The tempera-
• poor room conditions
ture of the
• output air temperature is out-
cabinet is too
side the specified range
high or too
low
• the cabinet is defrosting.
• the capacitor or the evaporator
are freezing.
• the capacitor or the evaporator
are obstructed or dirty.
• the load is not distributed even-
ly
Water leaks,
• The cabinet drains are blocked
or damaged
bad smell
• water collection tray is sealed
incorrectly
• water collection tray overflows • check wiring of evaporation heater
• insufficient joints between cabi-
nets in channel or joints not
sealed correctly
Frost or ice
in the cabinet
• fans do not work
in the evaporator
• heating elements broken
• Sdef probe detached
• air currents that alter the circu-
lation of refrigerated air
i
in all cases not described or where it is not possible to solve the problem by following these
directions call the nearest authorised after-sales centre.
29. Assembly instructions
i
the assembly instructions, after registration, are available at this address:
https://globalassistance.arneg.it/.
50
• tighten the bolts and screws
• level the counter
• check the position of the counter inside the
store
• check the operation of fans and wiring
• check electrical connections
• check the operation of heating elements
• close the windows properly
• check the position of the counter inside the
store
• check the operation of evaporator fan
• check wiring and input voltage
• the fans are installed reversely; check and re-
store the air flow direction
• check that fan plenum is sufficient and not
obstructed
• check the intake pressure that should comply
with rated specifications
• check defrosting parameters
• check that the suction line is not obstructed
• proceed with cleaning chap.23.4
• load the goods in an orderly fashion (Fig.13)
• free the drain
• repair or replace the drains
• seal it properly
• check the operation of evaporation heater
• install and seal the joints
• check electrical connections
• check the defrost parameters on the control-
ler
• check the ventilation inside the store