Descargar Imprimir esta página

Product Dimentions And Clearances - ELICA EAS428S2 Guía De Instalación, Uso Y Mantenimiento

Publicidad

Idiomas disponibles

Idiomas disponibles

Product Dimentions and Clearances

Location requirements:
IMPORTANT: Observe all governing codes and ordinances�
Have a qualified technician install the range hood� It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate� The model/serial
rating plate is located inside the liner behind the filter on the
left wall of the range hood�
• Range hood location should be away from strong draft
areas,such as windows, doors, and strong heating vents�
• Cabinet opening dimensions that are shown must be used�
Given dimensions provide minimum clearance� Consult
your cooktop/ range manufacturer installation instructions
before making any cutouts�
• Grounded electrical outlet is required� See "Electrical
Requirements" section�
The range hood is factory set for vented installations through
the roof or wall� For non-vented (recirculating) installations
see "Non- Vented (recirculating) Installation Through the
Soffit/Cabinet" in the "Prepare Location" section�
Recirculation Kit Part is available from your dealer or an
authorized parts distributor� All openings in ceiling and wall
where range hood will be installed must be sealed�
For mobile home installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225�1/NFPA 501A, or latest edition, or with local
codes�
C
E
F
A. 12" (30.5 cm) min. upper cabinet height
B. 30" (76.2 cm) cabinet opening width*
C. 24" (61 cm) min. 36" (91.4 cm) suggested
max. bottom of cabinet to cooking surface
*NOTE: This range hood is set to 30" (76�2 cm) cabinet width
x 12" (30�5 cm) deep cabinets�
A
B
D
D. 12" (30.48 cm) cabinet opening depth*
E. 15" (38.1 cm) min. clearance upper
cabinet to countertop
F. 36" (91.4 cm) base cabinet height
F
A
B
C
D
E
F
G
H
I*
I* - Metallic spacers has to be installed and used when cabinet depth is greater than 12".
For gas range installation: Mount this hood so that the bottom
edge is at minimum 30"(76�2 cm) above the cooking surface�
For electric range installation: mount this hood so that the
bottom is not less than 24"(61 cm) above the cooking surface�
H
C
EAS428S2
28
" (71�8 cm)
17
6 4
26" (66 cm)
1
9
" (3 cm)
6 4
10¾" (27�3 cm)
9
" (24�2 cm)
17
3 2
0
" (1 cm)
21
6 4
14
" (37 cm)
9
1 6
6" (15�2 cm)
½" (1�27 cm)
5

Publicidad

loading