Descargar Imprimir esta página

Publicidad

Enlaces rápidos

FLOW THROUGH
FURNACE HUMIDIFIER
HUMIDIFICATEUR
D'APPAREIL DE CHAUFFAGE À ÉCOULEMENT
FLUYE A TRAVÉS
DEL HUMIDIFICADOR
DEL SISTEMA DE CALEFACCIÓN
Installation &
Operating
Instructions
Instructions
pour l'installation
et l'utilisation
Instrucciones de
instalación y
funcionamiento
All manuals and user guides at all-guides.com
Model# Modèle n° Modelo N°
200G

Publicidad

loading

Resumen de contenidos para AutoFlo 200G

  • Página 1 All manuals and user guides at all-guides.com FLOW THROUGH FURNACE HUMIDIFIER HUMIDIFICATEUR D'APPAREIL DE CHAUFFAGE À ÉCOULEMENT FLUYE A TRAVÉS DEL HUMIDIFICADOR DEL SISTEMA DE CALEFACCIÓN Model# Modèle n° Modelo N° Installation & 200G Operating Instructions Instructions pour l’installation et l’utilisation Instrucciones de instalación y funcionamiento...
  • Página 2 All manuals and user guides at all-guides.com Check the package contents. Humidi er Assembly: A. Float Assembly, B. Motor, C. Cover, D. Drum Assembly, E. WaterPad®, F. Bypass Cap, G. Humidi er Base, H. Drain Assembly Hardware Kit: I. Wire Nuts (4), J. Hose Clamp, K. Large Screws (4), L. Small Screws (12) Humidi er Accessories: N.
  • Página 3 All manuals and user guides at all-guides.com L O W ( m o B O Y d è l e s u r b a i s s H I G é ) H B O ( m o H I G d è...
  • Página 4 All manuals and user guides at all-guides.com Incorrect Installations (1) Locate the “A” Coil (2) A. Do not drain humidi er into a bucket. You must have Does your furnace have central air conditioning? Furnaces the drain hose secured to a oor drain. equipped with central air conditioning have an “A”...
  • Página 5 All manuals and user guides at all-guides.com Mount and cut humidi er template Installing humidi er base on duct Mount template in correct position on ductwork making Partially screw in top 2 large screws. Mount humidi er sure it is level (G). Mark opening, cutting lines and holes base on screws.
  • Página 6: Installation Du Tuyau D'éVacuation

    All manuals and user guides at all-guides.com Left or Right bypass installation Attaching drain hose Determine which side the bypass ex duct will come o of C. Attach drain hose to bottom of humidi er and tighten the humidi er. The bypass cover can be mounted on the hose clamp to secure in place.
  • Página 7 All manuals and user guides at all-guides.com Mounting bypass duct collar Attach bypass ex duct Position the template in the correct place on the duct. G. Mount ex duct over duct collar. Use 2 screws to hold in Mark the screws and hole placement with a marking pen. place by screwing them into plastic collar.
  • Página 8 All manuals and user guides at all-guides.com Mounting the saddle valve Installing water line to oat Locate hot (preferred) or cold water pipe. Turn o water. Clean the pipe. A. Install plastic water feed line according to Be sure the piercing needle is not exposed beyond its rubber gasket. diagram above (insert, plastic grommet, brass Mount t-bar on top or side of water pipe.
  • Página 9 All manuals and user guides at all-guides.com Water level adjustment Installing humidi er lter and frame Some minor adjustment to oat assembly may be necessary. Water level should be to height indicated (C). There are 2 ways to adjust the Wrap BestAir®...
  • Página 10 All manuals and user guides at all-guides.com Mounting Humidistat on wall Installation de l’humidostat sur un mur Instalación del humidistato en la pared See mounting template Reportez-vous au gabarit d’installation Consulte la plantilla de instalación appropriate wall anchors (not supplied). 1.
  • Página 11 All manuals and user guides at all-guides.com Mounting Humidistat on duct Installation de l’humidostat sur un conduit Instalación del humidistato en el conducto See mounting template Reportez-vous au gabarit d’installation Consulte la plantilla de instalación 1. Turn power to your humidi er OFF. 6.
  • Página 12 All manuals and user guides at all-guides.com HUMIDISTAT WIRING TO 120V OF FURNACE WIRING TO 24V OF FURNACE HUMIDOSTAT HUMIDISTATO RACCORDEMENT À L’ALIMENTATION RACCORDEMENT À L’ALIMENTATION 120 V DE L'APPAREIL DE CHAUFFAGE 24 V DE L'APPAREIL DE CHAUFFAGE HUMIDISTAT HUMIDOSTAT CABLEADO DE 120 V DEL SISTEMA CABLEADO DE 24 V DEL SISTEMA HUMIDISTATO...
  • Página 13 All manuals and user guides at all-guides.com Relative Humidity Chart DO NOT OVER HUMIDIFY Outdoor Temperature Adjust % RH To Cold air cannot hold as much moisture as warm air. Any cold drafts or cold-faces such as windows and +30º F doors (including frames and jams) may cause water vapor to condense at these points.
  • Página 14 All manuals and user guides at all-guides.com Symptom Possible Causes & Remedies Water does not ow into humidi er 1. Saddle valve “T’ handle is not open 2. Saddle valve is clogged with mineral buildup 3. Float assembly is not adjusted correctly 4.
  • Página 15: Mantenimiento

    All manuals and user guides at all-guides.com Maintenance Annual Spring Shut-down All humidi ers require some maintenance to keep them operating at Turn o humidistat. Turn o water saddle valve. peak performance. The #BA200G has been designed to simplify this Close bypass damper.
  • Página 16 All manuals and user guides at all-guides.com BestAir Pro Hampshire, IL 60140 847-683-7990 www.bestairpro.com...