Position the interior air distribution panel on the
10
front studs with (1) M6 wide-rimmed washer
and (1) M6 nut on each stud. Tighten the nuts
until the foam duct comes up against the unit's
upper foam.
IMPORTANT: The rubber ducting must
being run into the upper rubber of the unit
to avoid air leaks.
10
EPDM
Gasket
Cabin roof
Upholstey
Tighten the nut in point 9a until it comes up
11
against the top part of the interior air distribution
panel.
11
EPDM
Gasket
Cabin roof
Upholstey
Place console and centre equipment in the
12
most convenient place of cabin roof. Once
centred, remove console for later installation.
All manuals and user guides at all-guides.com
Unit base
Nut M6
Stud M6
Unit base
Nut M6 (9a)
Nut M6
Stud M6
Rubber ductings
Rubber ductings
22
Air conditioning for vehicles
Foam
Interior air distribution
panel
Foam
Interior air distribution
panel