Checking the horizontal line side to side (Fig. 5)
1.
Set the instrument up approximately 8ft (2.5m) from a wall that is as least 16ft (5m) long.
2.
Project the laser cross 1ft(0.3m) from one corner. Mark point (A) along the horizontal laser
line 8ft (2.5m) from the intersection of the laser cross.
3.
Rotate the instrument so that the laser cross is projected at the wall 15ft (4.6m) away from
the first laser cross point.
4.
The deviation of the horizontal laser line from the point (A) marked previously should not be
greater than 1/2 the specified accuracy.
CALIBRATION
This unit is factory calibrated and should never need calibration. But if it needs to be calibrated, it
must be done by a factory authorized service center. Contact customer service at (815) 432-9200.
SAFETY AND CERTIFICATION
Working safely with this instrument is possible only when the operating and safety information are
read completely and the instructions contained therein are strictly followed.
Do not remove the label on the side of the housing.
The use in combination with other optical instruments, manipulations or use in other applications
other than described here, can lead to dangerous laser outputs.
Do not stare into the laser beam.
Do not direct the laser beam at other persons. Since the laser beam is of the focused type, check
the beam path over a relatively long distance and take the necessary precautions.
This laser complies with all applicable portions of title 21 of the Code of Federal Regulations set by
the Dept. of Health, Education, and
Welfare, the Food and Drug Administration, the Center for Devices, and the Bureau of Radiological Health.
The ILM has also been tested and complies with the CE certification requirements set forth in the
EC regulations 89/336/EEC and EN 61000-6-1 (EN50082-1), EN 61000-6-3 (EN50081-1)
and IEC 60-825-1.
All manuals and user guides at all-guides.com
Complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to Laser
Notice No. 50 dated July 26, 2001.