• The EFL 30 / EFL 30 C is particularly suitable for furniture constructions with soft closing
and self closing mechanisms.
• The EFL 30 / EFL 30 C is not suitable for drawers and hinged doors with a Push-to-Open
function.
• During installation, ensure there is an inspection opening available in case emergency
opening is required.
• During installation, note that access to the installed furniture lock must be guaranteed at all
times (e.g. by means of detachable drawers) for commissioning (visual signalling) and
maintenance purposes (battery change, reset).
• The control LEDs must be visible for commissioning.
• Observe the installation position:
• After assembly, mark the position of the lock (the antenna) on the outside of the furniture
using the antenna sticker supplied.
• Observe the minimum distance between two locks
• If the distance is less than the minimum distance, continuous communication will take place
between the locks, which will drain the battery.
5. Commissioning
The product is supplied in so-called simple operation mode for stand-alone operation (SA).
This document describes the commissioning process for stand-alone operation only.
Commissioning details for using the product with Dialock software applications can be found
in the Dialock software documentation.
Commissioning starts automatically after inserting the batteries or (when using the
external plug-in power supply unit PS 30) after plugging in the mains plug. The
individual steps must be carried out immediately and in sequence.
For safety reasons, the initial commissioning can only take place within 5 seconds
after the batteries were inserted.
• Read through the steps carefully before commissioning.
• Ensure both master keys (the "green" programming key card and "red" clearing key
card) are to hand before commissioning.
• Perform the work operations quickly and without interruptions.
If the commissioning time window is exceeded:
1. Remove the batteries.
2. Wait until the LED goes out.
3. Re-insert the batteries and restart the commissioning process.
Alternatively, commissioning can also take place by pressing the Reset button (
Product overview, page 39).
1. Press and hold down the reset button only until the first, short acoustic signal.
ATTENTION! If the button is pressed for longer, a reset will take place
(
Recommendation: carry out a firmware update with the MDU 110 mobile
programming unit before starting up in order to ensure that the most up-to-date
DIALOCK firmware is on the terminal.
44
10. Reset, page 56).
EFL 30 / EFL 30 C
EFL 30 / EFL 30 C
.
.