BEFORE YOU BEGIN
Tools and material needed
(not included)
UL
approved 7/8'' diameter strain
•
2 Wood blocks 7¼" maximum long x 2" minimum
•
height, thickness to fit cabinet dimensions (see
Prepare the cabinet on page 11)
Flat head no. 8 wood screws (to secure the wood
•
blocks to the cabinet)
Aluminum duct tape (DO NOT use insulating tape)
•
Measuring tape
•
Pencil
•
Drill
•
1/8" Wood drill bit
•
Saber saw or jig saw
•
Wire stripper or utility knife
•
Cross-shaped screwdriver no. 2
•
Tin snips
•
Safety glasses and work gloves
•
CAUTION
It is recommended to wear gloves and long sleeves to
protect hands and forearms from abrasion and potential
scratches during the installation process and servicing.
Parts supplied
Unpack the unit and check the content of the box.
A
B
OR
C
A: Parts bag containing: 8 Cross-shaped screws no. 8 x 3/8''
and 4 Cross-shaped screws, no. 8 x 3/4''
B: 6'' Ø duct connector for HUI34253UC, HUI30253UC or
HUI36253UC model
C: 8'' Ø duct connector for HUI80553UC or HUI86553UC
model
D: Unit shell
E: Unit module and frame assembly.
English 8
relief
D
E
Unit dimensions
A:
10½" (267 mm) unit with module and frame assembly
installed
A:
10¼" (260 mm) unit without module and frame assembly
installed
B: 6'' Ø duct connector: 2⅜"
B: 8'' Ø duct connector: 2⅛" (54 mm)
Parts not supplied
Charcoal fi lter kit (mandatory for recirculation installation
only). Refer below for the part numbers:
Unit Model
HUI34253UC
HUI36253UC
HUI86553UC
HUI30253UC
HUI80553UC
(60 mm)
Charcoal Filter Kit
HUIFIL46UC
HUIFILT0UC