Installation requirements
The ironer may only be commissioned by Miele Professional Ser-
vice or by a Miele specialist dealer.
The ironer must be installed in accordance with applicable regula-
tions and standards. Local energy supplier regulations must also be
observed.
Operating conditions
In general, the operating conditions of DIN 60204 and EN 60204-1
apply.
- Ambient temperature: +5 °C to +40 °C
- Humidity: 10 % to 85 %
- At +21 °C ambient temperature, the maximum permissible relative
humidity is 70 %.
The ironer must not be operated in the same room as dry-clean-
ing equipment using perchloroethylene or solvents containing
CFCs.
Installation
The ironer should be transported to the installation site using a suit-
able pallet truck. Do not remove the packaging until right before the
appliance is used for the first time.
The lateral mounting flaps must be fitted before transporting the
ironer or lifting it off the wooden frame.
The suspension points for lifting hooks/straps are located under the
side columns between the screw-on feet.
During installation, ensure that the clearance next to and behind the
machine columns is at least 600 mm so that the cover panels remain
accessible.
The clearance in front of the ironer must amount to at least 1.5 m to
prevent foreign materials (furniture, walls) from getting hot. There
should be a clearance of at least 1 m above the machine.
During transportation of the ironer, ensure its stability. The ironer
must not be transported without the wooden frame.
If the ironer needs to be transported again (e.g. if you are moving
location), it must be lifted onto the wooden frame and secured on
it.
Levelling
To ensure the ironer functions correctly and energy efficiently, it
must be levelled horizontally with the screw feet.
en - Installation and planning notes