en - Installation and planning notes
12
Dismantle the mounting flaps on the left and right sides.
Align the roller and the side columns using the screw feet and a
spirit level. The screw feet under the side columns can be un-
screwed to a maximum of 60 mm.
After levelling the machine secure the screw feet so they cannot
come loose.
Floor anchoring
Suitable anchoring materials for the ironer are available as optional
accessories from the Miele Professional Service Department. Altern-
atively, the tensioning strips that secured the ironer to the transport
pallet for delivery may be used to anchor the machine to the floor.
4 0 m m
2 0 m m
Tensioning strip from the transport pallet
Coin operated ironers must be secured by the side columns to pre-
vent the risk of the machine tipping.
Electrical connection
The electrical connection must be carried out by a qualified electri-
cian who must ensure that all electrical work is completed in ac-
cordance with applicable regulations and standards.
The electrical connection and the wiring diagram are located behind
the mounting flap of the right side column.
Tip: We recommend connecting the ironer to the power supply via a
plug and socket so that it is easier to conduct electrical safety checks
(e.g. during maintenance or repair work).
If the machine is hard wired, an all-pole means of deactivation must
be installed on site. Switches with a minimum contact gap greater
than 3 mm are suitable disconnectors. These include circuit breakers,
fuses and contactors (VDE 0660).
The plug connector or isolator switch should be easily accessible at
all times.