Appendix 1 Simple Application
1-1 Example
Use external end (three phases) to control running of Inverter,
use external terminal to switch rotation forward or reverse. The
potentiometer controls frequency of Inverter.
A: Basic connection illustration:
Three phase
power supply
10K
K3
B: Parameter setting and instruction:
F1.01=1 the measure of analog voltage setting
(Potentiometer of external terminal)
F1.02=1 external terminal control
F3.17=6 define the terminal S1 turning forward
F3.18=7 define the terminal turning reverse
F3.19=8 define terminal S3 stopping
C: Action instruction:
K1 running forward
K1 running forward
Manual de Funcionamiento del variador de la serie H5000
Example
R
S
T
+10V
FIV
FC
K1
K2
S1
S2
S3
Sc
248
Appendix 1 Simple Application Example
U
V
W
E
M
Motor