Operation Instruction of H5000 Series Inverter
2-3 Description of Register Address:
1) 2000H: Stop command
2) 2001H: Setting command (0~400.00HZ)
Frequency of F1.01=5 is from 2001H
Frequency of F1.01=0 is from F1.00
3) For example:
a) Functional code F0.03(Current)
Address: 3 (Hexadecimal: 00H 03H)
b) Functional code F0.05 (Speed)
Address: 5 (Hexadecimal: 00H 05H)
c) Address: F1.00 (Main frequency)
Address: 100 (Hexadecimal: 00H 64H)
d) Functional code F1.01 (Frequency source)
Address: 101 (Hexadecimal: 00H 65H)
e) Functional code F1.07 (Acceleration time)
Address: 107 (Hexadecimal: 00H 6BH)
f) Functional code F1.08 (Deceleration time)
Address: 108 (Hexadecimal 00H 6CH)
And so on...
2-4 Data address
Data
address
Local address
BIT0~BIT1
2000H
BIT2~BIT3
_48193
BIT4
BIT5~BIT15 Reserved
Manual de Funcionamiento del variador de la serie H5000
00B: none
10B: start
00B: none
10B: forward
0B: none
258
Content
01B: stop
11B: JOG start
01B: reverse
11B: change direction
1B: reset
Read/write
Write
Write
Write