CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved could void your authority to use this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
CAN ICES-005 (B)/NMB-005 (B)
ELECTRICAL CONNECTIONS- STANDARD LUMINAIRE ( NO EMERGENCY BACKUP)
STEP 1:
Make the following Electrical Connections::
a. For 120/277V connect the black fixture lead to the voltage
supply or Hot 1 (for 208/240V wiring).
b. For 120/277V connect the white fixture lead to the neutral
supply or Hot 2 (for 208/240V wiring).
c. Connect the green or green/yellow supply ground lead to the
junction box
d. If 0/1-10V Dimming is used, connect the violet lead to the
supply positive dimming lead. If dimming is not being used
ensure to cap off the violet lead. For dimming connections,
use Class 1 wiring methods.
e. If 0/1-10V Dimming is used, connect the grey or pink lead to
the supply negative dimming lead. If dimming is not being
used ensure to cap off the grey or pink lead. For dimming
connections, use Class 1 wiring methods.
4 of 5
EMERGENCY INDICATOR LIGHT STATUS
(For Lumainires Equipped With Emergency Driver Accessory)
INDICATOR STATUS
EMERGENCY DRIVER STATUS
Battery Is Charging
Battery Is Fully Charged
Battery Is Under voltage, Needs To Be Charged
Battery Is Discharging
LINE
OR HOT 1
**GREEN
NEUTRAL
OR HOT 2
DIM (+)
DIM (-)
**Connect the green or green/yellow supply ground lead to the junction box
LUMINAIRE
LINE-BLACK
**GROUND-GREEN
OR
GREEN/YELLOW
NEUTRAL-WHITE
DIM (+) VIOLET
DIM (-) GREY
OR PINK