Descargar Imprimir esta página

Dyna-Glo Delux RMC-KFA400TDGD Manual Del Usuario E Instrucciones Para El Funcionamiento página 13

Calentadores portatiles de aire forzado de querosen

Publicidad

Idiomas disponibles

Idiomas disponibles

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
G.) FUEL FILTER
CLEAN TWICE PER HEATING SEASON OR AS NEEDED.
Tank Fuel Filter
- Remove fan guard.(See page 11).
- Disconnect fuel line (B) from pump and pump
fuel filter assembly with 3/8" wrench
(See Figure 14)
- Carefully pry fuel filter loose from fuel tank with
flat end of screw driver.
- Wash fuel filter and fuel lines with clean kerosene.
- Replace fuel filter into fuel tank.
- Connect fuel lines (B) to pump and pump fuel
filter assembly.
- Reinstall fan guard.
Pump Fuel Filter
- Remove fan guard.(See page 11)
- Unscrew (C.W) filter bottom from filter top
with adjustble pliers.
- Remove fuel filter, gasket, magnet from filter
bottom.(See Figure 15)
- Wash filter bottom with clean kerosene .
- Wipe inside of filter bottom dry with clean cloth.
- Wash Fuel filter in clean kerosene.
- Remove dirt attached magnet.
- Put clean magnet, fuel filter and gasket back in
filter bottom.
- Tighten firmly.
All manuals and user guides at all-guides.com
12
PUMP
FUEL LINE(B)
FUEL FILTER
PUMP FUEL FILTER ASSEMBLY
Figure 14. Remove Tank Fuel Filter
FUEL FILTER
MAGNET
FILTER BOTTOM
Figure 15. Fuel Pump Filter
FILTER TOP
GASKET