Installation Guide
T942C- and T942C/2 Central Unit
Opening the Housing from the Front
If the housing has to be mounted without sufficient space below it, the cut-out holes in
the housing lid should be opened to facilitate maintenance.
Cut Out
Figure 5. Cut outs for opening the cover.
When the holes are opened, a screwdriver can be used to open the lid. Apply a slight
downward pressure (1), then gently lever the screwdriver downwards (2), the clips which
hold the lid will then be released and the cover can be removed (3).
Figure 6. Removing the cover.
To replace the circuit board, see 1.3.19 Circuit Board Replacement on page 20.
2003-01-08 / Rev.C
Cut Out
Handook page
9/128
TD 91684GB