Installation Guide
T942C- and T942C/2 Central Unit
1.3.10 Connection of Reference Module in a FL-System (used only in paging
1.3.11 Connection of absent indication from teleCOURIER 800 System Charging

1.3.12 Connection of Monitor Input

2003-01-08 / Rev.C
systems)
Connect a twisted-pair from connector J12 screw 6 and 2 to Reference Module T938RM
connector J04 screw 5 and 6, respectively (polarized!).
T942C
J12
GND 6
OUT1 (CODE1) 2
1
T938RM
J04
REF ON 6
GND 5
Figure 17. Connection of the Reference Module to the Central Unit.
Note: The digital outputs must be provided with supply voltage, see 1.3.9 Connection of
Supply Voltage on page 13.
Rack T862
Connect absent indication from Charging Rack T862 connector A screw 3 and 4, to
T942C connector J11 screw 1 and 5. (See also drawing no. OE 8578-4A).
T942C
IN4 (ABS) 5
+12V 1
T862
Connector A
RE1
Figure 18. Connection from Charging Rack to the Central Unit
Note: The digital inputs must be provided with supply voltage, see 1.3.9 Connection of
Supply Voltage on page 13.
In some cases it may be desirable to prevent the paging transmitters from transmitting,
e.g. when a carrier wave is already in the air.
Monitor input can be used to prevent the Central Unit both from activating the output
stage in the transmitters and from sending the transmitter code to them when a carrier
wave is in the air.
J11
6
3
4
TD 91684GB
14