W11581317 L.P. (Propane and Butane) Gas Conversion Kit
Converting 20,000 BTU/hr Gas Burners from Natural Gas to Liquefied Petroleum (Bottled Gas)
Parts Included in Kit:
1 Instruction Sheet
1 Blocking Pin Style "A"
1 Blocking Pin Style "B"
1 Orifice, Burner-Butane Number .049
1 Orifice, Burner-Propane Number 55
1 Label, Rating Plate Conversion (English, French, Spanish)
1 Label, Conversion Record (English, French, Spanish)
• For 27" Front Console Dryers See
• For 27" Rear Console Dryers See
WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all
applicable codes and requirements of the authority having jurisdiction. The information in these instructions must be followed to
minimize the risk of fire or explosion or to prevent property damage, personal injury, or death. The qualified service agency is
responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted
appliance is checked as specified in the manufacturer's instructions supplied with this kit.
NOTE: A qualified service technician is any person or representative of a company who is experienced or trained in servicing gas
equipment and is familiar with necessary precautions.
Canada Only
THIS CONVERSION KIT SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN-B49.1 AND CAN1-B149.2 INSTALLATION CODE.
NOTE: Read these instructions before proceeding.
IMPORTANT: The LP Conversion Kit you received is an approved kit for converting your gas dryer from natural to LP propane or butane
gas. The kit number shown on the Burner Data Label located on the Burner Base may not match the kit you receive due to kit
consolidation.
This dryer has been manufactured for use with Natural Gas. Installation of this conversion kit converts the dryer for use with L.P. gas
with supply pressure between 8" (203 mm) and 13" (330 mm) water column. If this dryer is converted for use with L.P. gas by means of
this kit, the input rating will be 20,000 BTU's per hour, for altitudes up to 10,000 feet (3,048 m). For installations above 2,000 feet
(610 m), contact a qualified service agency for derating instructions.
W11581423 Rev A
Instruction Sheet
Disassembling the Dryer
Section 1
Section 2
WARNING
Electrical Shock Hazard
Disconnect power before servicing. Replace all
parts and panels before operating. Failure to do so
can result in death or electrical shock.
1 Label, Burner Baseplate (English, French, Spanish)
Tools and Accessories Required:
Wrench 1/4" Nut Driver
5/16" Nut Driver
Phillips-Head Screwdriver
T20® Torx®
Head Screwdriver
*
Pliers or Flat-Head Screwdriver
+® Torx and T20 are registered trademarks of Acument Intellectual
Properties, LLC.
1
1/4" Socket and Ratchet