CONTROL FUNCTION
3 In 1 switch knob
v
Engine switch \fuel valve \choke.
is switched on. Fuel is switched on. Choke is switched on.
The engine can be running.
w
Engine switch \fuel valve \choke.
is switched on. Fuel is switched on. Choke is switched on.
The engine can be start.
Tip: The choke
is not required to start a warm engine.
Oil warning light
Tip: If the engine stalls or does not start, turn the engine
switch to "ON" and then pull the recoil starter.
If the oil warning light flickers for a few seconds,
the engine oil is insufficient. Add oil and restart.
Overload indicator light (Red)
Then, the AC protector will trip, stopping power generation
in order to protect the generator and any connected electric
devices. The AC pilot light (Green) will go off and the
overload indicator light (Red) will stay on, but the engine will
not stop running.
When the overload indicator light comes on and power
generation stops, proceed as follows:
1. Turn off any connected electric devices and stop
the engine.
2. Reduce the total wattage of connected electric devices
within the rated output.
3. Check for blockages in the cooling air Inlet and around
the control unit. If any blockages are found remove.
4. After checking, restart the engine.
Tip: The overload indicator light may come on for a few
seconds at first when using electric devices that
require a large starting current, such as a compressor
or a submergible pump. However, this is not a
malfunction.
u
Engine/fuel valve
"OFF"; lgnition circuit is
switched off. Fuel is
switched off. The engine
will not run.
"ON" Ignition circuit
"ON" Ignition circuit
When the oil level falls below
the lower level, the oil
warning light comes on and
then the engine stops
automatically.
Unless you refill with oil, the
engine will not start again.
The overload indicator light
u
comes on when an
overload of a connected
electrical device is detected,
the inverter control unit
overheats, or the AC output
voltage rises.
AC pilot light (green)
DC protector
NOTICE
Reduce the load of the connected electric
device below the specified rated output of the
generator if the DC protector turns off.
If the DC protector turns off again, stop using
the device immediately and consult a
franchised dealer.
Frequency selection (FS) switch only for 100V product
Frequency selection
NOTICE
Frequency switch can change frequency only
when the generator setting stops.
The generator setting output frequency can't
change if it operates.
4
u
The AC pilot light
comes
on when the engine starts
and produces power.
The DC protector turns
v
to "OFF"
automatically
when electric device being
connected to the genera-
tor is operating and current
above the rated flows. To
use this equipment again,
turn on DC protector by
pressing its button to "ON"
u
.
u
"ON" Direct current
is output.
v
"OFF" Direct current
is not output.
u
50Hz
v
60Hz If you need change
the machine output
frequency, please stop
the generating set firstly,
then adjust the position
of frequency switch by
screwdriver. Then