Descargar Imprimir esta página

Application Range; Maintenance - KNOVA KN GENI-23 Manual Del Usuario

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
AC parallel operation applications
Tip:
• Make sure that it is in good working order. A faulty
appliance or power cord can create a potential for
electrical shock.
• If an appliance begins to operate abnormally, becomes
sluggish, or stops suddenly, turn if off immediately.
Disconnect the appliance and determine whether
the problem is the appliance, and determine whether
the problem is the appliance or the rated load capacity
of the generator has been exceeded.
• Make sure that the combined electrical rating of the tools
or appliance do not exceed that of the generator. Never
exceed the maximum may be used for no more than
30 minutes.

APPLICATION RANGE

When using the generator, make sure the total load is within rated output of a generator.
Otherwise, generator damage may occur.
AC
Power factor
KN GENI-23
Tip:
• "-" means below.
• Application wattage indicates when each device is used
by itself.
• The simultaneous usage of AC and DC power is possible
but total wattage should not exceed the rated output.
Ex.
Generator rated output
Power factor
Frequency
AC
DC
The overload indicator light comes on when total wattage
exceeds the application range. (See page 4 for more details.).

MAINTENANCE

Safety is an obligation of the owner. Periodic inspection,
adjustment and lubrication will keep your generator in
the safest and most efficient condition possible. The most
important points of generator inspection and lubrication are
explained on the following pages.
WARNING
If you are not familiar with maintenance
work, have a franchised dealer do it for safety.
1
~ 1800 W
~ 1440 W
1800 VA
~ 1800 W
1.0
0.8
~ 1440 W
100 W (12 V / 8.3 A)
--
• Never connect different generator models.
• Don't remove the parallel operation cable when
the generator operation.
• For single generator operation, the parallel operation
cable must be removed.
NOTICE
0.8 - 0.95
(efficiency 0.85)
NOTICE
• When supplying precision equipment, electronic
controllers, PCs, electronic computers, microcomputer
based equipment or battery chargers, keep the generator
a sufficient distance away to prevent electrical
interference from the engine. Also ensure that electrical
noise from the engine does not interfere with any other
electrical devices located near the generator.
• If the generator is to supply medical equipment, advice
should first be obtained from the manufacturer, a medical
professional or hospital.
• Some electrical appliances or general-purpose electric
motors have high starting currents, and cannot therefore
be used, even if they lie within the supply ranges given in
the above table. Consult the equipment manufacturer for
further advice.
Maintenance chart
WARNING
maintenance work.
Use only franchised dealer specified genuine parts for
replacement. Ask an authorized franchised dealer for further
attention.
8
• Substantial overloading that continuously
lights the overload indicator (red) may
damage the generator Marginal overloading
that temporarily light the overload indicator
(red) may shorten the service life of
the generator.
• For continuous operation, do not exceed
the rated power.
• Rated power in parallel operation is: 3.6 kVA.
0.4 - 0.75
~ 720 W
Rated current 8.3 A
• Do not overload. The total load of all
electrical appliances must not exceed the
supply range of the generator.
Overloading will damage the generator.
Stop the engine before starting
DC
Rated voltage12 v

Publicidad

Solución de problemas

loading