Description of contacts
Power supply: 3-4 time relay power supply;
Channel 1: 1-5 «normally open» position;
1-6 position «normally closed»;
Channel 2: 2-7 position «normally open»;
2-8 position «normally closed».
Connection diagrams
Connection diagram of the product and the load to the 230V
network.
N
L
1
2
5
6
Wiring diagram using a contactor, load current more than 16A.
N
L
1
2
3
4
5
6
7
8
Connection diagram for devices and loads powered by different
sources.
N
L
Rн2
Rн1
Rн1, Rн2 - connected loads;
К – the coil of the contactor.
Connection
1. Disconnect the power supply.
3. Connect the power wires according to the diagram.
2. Mount the relay on a DIN rail in the enclosure.
4. Connect the load according to the diagram.
5. Supply power.
Description of operating modes and
functions
Automatic mode - automatic operation by programmed
switch-on and switch-off points [clock icon on the indicator of
the corresponding channel].
Semi-automatic mode - the ability to manually turn on / off the
relay contacts during operation in automatic mode. The change
will remain in effect until the next on / off based on the auto cycle
[flashing clock icon of the corresponding channel].
3
4
Rн1
Rн2
7
8
Rн1
Rн2
K
K
24-264V
AC/DC
1
2
3
4
5
7
8
6
ATTENTION!
In semi-automatic mode, the position of the relay contacts will be
opposite to the running program. Semi-automatic mode is active
only until the end of the current cycle of automatic operation, for
example, entering the semi-automatic mode during the day will turn
on the light until the start time comes, based on the astronomical
program. Then the product returns to automatic mode, and the
lighting remains on until the morning shutdown). The mode is
switched on or off using the «+/–» buttons (for the first and second
channels, respectively) in the clock display mode (main mode).
Manual mode: [ON] - contact is permanently closed, or [OFF] -
contact is permanently open. When automatic mode is off
(there is no icon on the indicator).
Astronomical sunrise and sunset are the moments when the
center of the solar disk touches the horizon.
Programmed switch-on and switch-off points - contact
switch-on and switch-off times, assigned according to
astronomical sunrise / sunset, night breaks or weekly program.
Night Break is a user-defined, temporary shutdown between
software on and off points.
Localization (location) - geographic coordinates and time
zone of the settlement where the relay is installed. You can
enter your own geographic location and time zone (UTC)
coordinates, or use city codes.
City codes - to facilitate the entry of information, some
localities have been assigned codes (coordinates and codes
are given in Table 1).
Correction - acceleration or deceleration of on / off in relation
to astronomical sunrise and sunset times: ± 240 minutes - on /
off time correction relative to sunrise / sunset time.
Automatic time change - change from winter to summer time
and back. There are options for working with automatic
transition, or without it. The time relay is in the function of
binding to the time zone, so the transition will occur relative to
local time.