WIRING
WARNING
!
Risk of electric shock. Electrical wiring must be
done by qualified personnel in accordance with all
applicable codes and standards. Before connecting
wires, switch power off at service panel and lock
service disconnecting means to prevent power from
being switched on accidentally.
1. Using appropriate wire nuts (not included), connect house
power cable to unit wiring: BLACK to BLACK, WHITE to
WHITE and GREEN or bare wire to GREEN ground screw
(FIG. 30).
2. Reinstall the electrical cover in the unit; ensuring the bottom
tabs are inserted in their embossed location. Secure in
place using its retaining screw (FIG. 31).
CAUTION
Take care not to pinch wires while reinstalling wiring
cover.
INSTALL THE FILTERS
Ducted Installation
Reinstall the hybrid baffle filters.
Non-Ducted Installation
Attach the non-ducted filters (included with the HARKBN24
or HARKBN30 non-duct kit) to the back of the hybrid
baffle filters using clips (provided with non-ducted filter).
To order new non-ducted filters, use service part number
S99010464-124 for HBN1246SS and S99010464-130
for HBN1306SS model.
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the following two
conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
FCC/IC Statements
Contains FCC ID: 2AC7Z-ESP32WROVERE
Contains IC: 21098- ESPWROVERE
WHITE WIRE
GREEN
GROUND
SCREW
BLACK
WIRE
HOUSE
POWER
CABLE
FIG. 30
TABS
FIG. 31
15