4.5 INSTALLATION DIAGRAM
TYPICAL INSTALLATION OF A 3 PISTONS PUMP FOR AGRICULTURAL APPLICATION
TYPICAL INSTALLATION OF A 6 PISTONS PUMP FOR AGRICULTURAL APPLICATION
All the six piston pumps series C-CK feature an internal connection of outlets with clear passage of
14mm.
46
REFERENCES
1. Pump.
2. Pressure gauge.
3. Safety valve
4. Safety valve by-pass
5. Pulsation dampener.
6. Discharge line.
7. Pressure regulating
valve.
8. Pressure regulating
unit by-pass.
9. Outlet for agitation.
10. Agitators.
11. Inlet line.
12. Suction filter.
13. On line filters.
14. Nozzles
15. Tap to set to zero
pressure when starting
the pump
16. Tank.
17. Inlet manifold
18. Outlet manifold