Descargar Imprimir esta página

Manual Accumulation; Automatic Accumulation; Battery Operation - Baxtran BW Serie Manual De Usuario

Ocultar thumbs Ver también para BW Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

6.8 MANUAL ACCUMULATION

When the scale is set to manual accumulation the weight displayed will be stored in memory when the
weight is stable.
The display will show "ACC 1" and then the total in memory for 2 seconds before returning to normal. If the optional RS-232 interface
is installed the weight will be output to a printer or PC.
Remove the weight, allowing the scale to return to zero and put a second weight on. Press
then show the new total. Continue until all weights have been added.
To view the totals in memory press the
xx" and the total weight before returning to zero. The totals will also be printed via the RS-232 interface.
To erase the memory press

6.9 AUTOMATIC ACCUMULATION

When the scale has been set to Automatic Accumulation the value is stored in memory automatically.
Add a weight to the scale, the beeper will sound when the scale is stable to signify the value is accepted. Remove the weight.
The display will show "ACC 1" and the totals in memory when the scale returns to zero. Adding a second weight will repeat the process.
While the weight is on the scale it is permissible to press the
store the value when the weight is removed.
The totals can be viewed as above.
In all cases the scale must return to zero or a negative number before another sample can be added to the memory.
More product can then be added and
is exceeded.

7. BATTERY OPERATION

The scales can be operated from the battery if desired. The battery life is approximately 100 hours.
As the battery is used it may fail to hold a full charge. If the battery life becomes unacceptable then contact your distributor.
10
key when the scale is at zero. The display will show the total number of items "ACC
to view the totals and then press the FUNC/C key to clear the memory.
pressed again. This can continue for up to 99 entries, or until the capacity weight display
When the battery needs charging the arrow above the low battery symbol under the weight
display will turn on. The battery should be charged as soon as the arrow above the symbol is
on. The scale will still operate for about 10 hours (without backlight) after which it will auto-
matically switch off to protect the battery.
To charge the battery simply plug into the mains power. The scale does not need to be turned
on.
The battery should be charged for 12 hours for full capacity.
Just under the quantity display is an LED to indicate the status of battery charging. When the
scale is plugged into the mains power the internal battery will be charged. If the LED is green
the battery has a full charge. If it is Red the battery is nearly discharged and yellow indicates
the battery is being charged.
key to store the value immediately. In this case the scale will not
USER'S MANUAL BW
key is pressed and the
, the display will show "ACC 2" and
EN
EN

Publicidad

loading