6.6 CHECK WEIGHING
Check-weighing is a procedure to cause an alarm to sound when the weight on the scale meets or exceeds values stored in memory.
The memory holds values for a high limit and a low limit. Either limit can be used or both can be used.
Press the
key. The display will show the current High Limit with the left most digit flashing and the HI symbol on to the left of
the display.
To change the value shown use the
flashing digit.
When the desired value is shown press the
to clear the value.
After pressing the
key the display will then s how the Low Limit, the LO symbol will be on to the left side of the display.
Enter the low limit in the same way the high limit was entered.
After pressing the
key the scale will return to weighing with the Check weighing function enabled.
When a weight is placed on the scale the arrows will show if the weight is above or below the limits and the beeper will sound as
described below.
BOTH LIMITS SET
The display will show OK and the beeper will sound when the weight is between the limits.
LOW LIMIT SET,
HIGH LIMIT is set to zero
The display will show OK and the beeper will sound when the weight is less than the Low Limit. Above the Low Limit the display will
show HIGH and the beeper will be off.
HIGH LIMIT SET,
LOW LIMIT is set to zer zero
The display will show LOW and the beeper will be on when the weight is less than the High Limit. Above the High Limit the display will
show
OK and the beeper will be off.
BOTH LIMITS SET. LOW IS SET GREATER THAN HIGH
The beeper will sound and the display will show LOW if the weight is less that the LOW limit, and HIGH if the weight is greater than the
Low Limit.
NOTE: The weight must be greater than 20 scale divisions for the check weighing to operate.
To disable the Check-Weighing function enter zero into both limits by pressing the
pressing the
key to store the zero values.
6.7 ACCUMULATED TOTAL
The scale can be set to accumulate automatically when a weight is added to he scale or manually by pressing the
PARAMETERS Section for details of selecting the method. The accumulation function is only available when weighing. It is disabled
during percent weighing or parts counting.
and the
to select the digit to change. Then use the
key to accept the value. If you want to reset the value to zero press the
USER'S MANUAL BW
key to increment the
key when the current limits are shown then
EN
EN
key
key. See the
9