Descargar Imprimir esta página

Gas Connection; Conversion To Other Types Of Gas - Fagor SB-G910 Instrucciones De Instalación, Uso Y Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
PICTURE 1
Make electrical connection and re-tie electrical box
4.5

Gas connection

An AUTHORISED TECHNICIAN should always carry out the gas connection of the appliance.
4.6

Conversion to other types of gas

If the appliance is prepared for a different type of gas to the one available in the installation, you
should proceed as follows:
1. Disconnect the gas supply to the appliance if connected (Any change to the conditions of the
gas circuit must be carried out by an AUTHORISED TECHNICIAN).
2. Burner conversión:
a. Remove the front panel of the tilting Bratt pan.
b. Remove the burner injector and replace with the correct model according to the gas
c. Set the air control to position H (table 3) depending on the gas to be used.
d. Replace the front panel.
3. Pilot conversión:
a. Remove the front panel of the tilting Bratt pan.
b. Undo the pilot unit.
c. Remove the pilot injector and replace with the correct model according to the gas to
d. Turn the air control to open or close the opening according to the gas type (table 3).
e. Replace the pilot unit.
f.
PICTURE 2
• The general installation must have a main tap and a pressure regulator and it is
also advisable to install a shut-off cock on each individual appliance.
• A pipe of at least Ø 12 x 10 mm should be used for the gas connection, together
with a ¾" nut to connect to the tilting bratt pan.
to be used (table 3).
be used (table 3).
Replace the front panel.
PICTURE 3