Alarm of heat
1 x per 0.3 second
Alarm silence
1 x per 8 seconds
Low battery warning
2 x per 48 seconds
Low battery warning silence
1 x per 48 seconds
Sensor fault warning
2 x per 48 seconds
Wireless alarm
None
End of life warning
3 x per 48 seconds
Wireless interconnecting
Continuously on
HOW TO MUTE ALARMSOUND
Alarm/ Low battery warning/
ONLY AFTER RECOMMENDED ACTIONS HAVE BEEN TAKEN
Sensor fault warning
If the alarm fails to operate, the advice of the manufacturer should be sought.
.
10
Wireless functions
(see page 5)
Interconnect your alarms
a)
Place the interconnected alarms as close as possible, not further than 5 meters apart.
b)
Choose one interconnected alarm as Master. Press 3 times its test/silence button. The LED light will turn on.
c)
Choose another interconnected alarm as Slave. Press 3 times its test/silence button. The LED light will turn
on.
d)
Wait a few seconds until the slave device beeps and turns off its LED, indicating successful network pairing.
e)
Repeat step b) for connecting more interconnected alarms.
NOTE: always use the same Master alarm for connecting additional Resideo interconnected smoke, heat or
carbon monoxide (CO) alarms, now and in future. Write down which interconnected alarm in your home is the
Master. And you can only enable pairing when the mounting plate has installed.
After the master alarm enters interconnect mode for pairing, it will automatically exit connection mode within 40
seconds, and this 40-second period will be extended by another 40 seconds after each successful pairing. After all
interconnected alarms are connected, the master can also manually exit by pressing the test/silence button three
times if the master device has not yet exited the pairing mode.
Test your interconnection
Hold down the test/silence button.
The initial interconnected alarm will beep continuously with the LED flashes at the same rate.
1 x per 0.3 second
Device is detecting heat
None
If the Alarm signal is muted, lasting
for approx. 10 minutes
1 x per 48 seconds
Battery is running low
None
If Low battery warning is muted,
lasting for approx. 8-10 hours
None
Sensor is not functioning properly
1 x per second (3 x) /
Device received remote alarm from
pause of 1,5 seconds
other device.
3 x per 48 seconds
Device is end of life
None
Device is sending or searching for
wireless signal
Press cover test/silence button for
2 seconds