4�4
TIG parameter settings table
Process parameters can be set directly using the following sequence:
♦
press B
♦
turn B to select a single parameter
♦
press B to enter parameter modification mode (the parameter turns red)
♦
turn B to select the desired value
♦
press B again to exit modification mode.
♦
press B without releasing immediately to set the default value.
48/65
Description
Pre-flow duration
EVO START (**)
(TIG DC HF)
Hot Start AC
(TIG AC HF)
(TIG MIX HF)
First Level Current
First Level Duration
Initial Ramp Duration
Main Current
Intermediate current
Final Ramp Duration
Crater Current Duration
Crater Current
Duration
postflow
Min�
DEF
0.1
0.1
OFF
OFF
0.1
1.6
3
25
0
0
0
1.0
3
100
5
50
0
1.0
0
0
3
10
0.1
10
Table 1
Max
UM
Sol�
10
s
0.1
1.0
s
0.1
6.0
mm
0.1
I_SET
A
1
30
s
0.1
10
s
0.1
I2_max(*)
A
1
I2_max(*)
A
1
10
s
0.1
10
s
0.1
I_SET
A
1
50
s
1 (0.1-25) s
5 (25-50) s
3301286