ERROR CODES
Error management is divided into two categories:
Hardware errors [E]. These cannot be reset and require the power source to be restarted. They are displayed on the
screen with a red background.
Alarms [W] linked to an external condition that can be reset by the user and does not require the power source to be
restarted.
These are displayed on the screen with an amber background.
Code
Type
3
[E]
General fault error detected by the power source
internal slave board
6
[E]
Communication error detected by master panel
board on CAN-bus
10
[E]
Power output nil (I=0A, V=0V)
11
[E]
Overload at output
13
[E]
Problem on the PFC control board, the DC bus
is not set properly.
14
[E]
Undervoltage error detected on inverter control
board.
20
[E]
Interlock signal absent
25
[E]
Excessive primary winding current error
28
[E]
Fan malfunction
30
[E]
Output current sensor offset reading problem
32
[E]
Voltage measuring reference out of specifications Check there are no voltages connected to the
54
[E]
Power source test voltage nil or V Out > 48 VAC Switch the power source on and off. If the error
58
[E]
Firmware upgrade error
63
[E]
Incorrect mains voltage value
74
[W]
Thermal protection triggered due to excessive
temperature in primary circuit TH1
75
[W]
Coolant pressure too low.
64/65
Error Description
Action
Switch the power source off and on. If the
problem persists, contact technical assistance
Switch the power source on and off. If the error
persists, contact technical assistance.
Hardware error, contact technical assistance.
Probable break in inverter circuit of primary
winding
Hardware error, contact technical assistance.
Hardware error, contact technical assistance.
Check machine supply voltages. If the problem
persists, contact technical assistance.
Switch the power source off and on. If the
problem persists, contact technical assistance
Switch the power source on and off. If the error
persists, contact technical assistance. Probable
break in output diodes or primary winding
inverter circuit.
Check there are no mechanical blockages in the
rotating parts of the fan. If the problem persists,
contact technical assistance.
Switch the power source on and off. If the error
persists, contact technical assistance.
machine output terminals upon ignition. Switch
the power source on and off. If the error persists,
contact technical assistance.
persists, contact technical assistance.
Contact technical assistance. or impose firmware
update by turning DIP3 on the panel board ON.
Check that the mains plug phases are properly
connected.
If the error persists, contact technical assistance.
Wait until the machine cools down. Check that
the air intake and outlet grilles are not blocked.
If the problem persists, contact technical
assistance.
Check the coolant level. Check the centrifugal
pump turns correctly. If it does not turn correctly,
release using a release screw. If the problem
persists, contact technical assistance.